Furnace error code lookup

Pick your brand and type the code (or the number of flashes) you see on the unit. You'll get what it usually means and the first safe things to check.

Codes vary by model. These are the most common meanings. Always confirm with the code chart printed on the inside of your furnace door. If you smell gas, leave the house and call your gas company from outside.

Carrier / Bryant / Payne furnace codes

How to read them: Look through the small window on the blower door. The LED flashes a 2-digit code: a group of long-ish flashes for the first digit, a short pause, then flashes for the second digit (for example 3 flashes, pause, 1 flash = code 31).

CodeWhat it meansWhat to check first
11No previous fault stored (or the fault history was just cleared).Normal after a reset. If the furnace still does not heat, check the thermostat and power first.
12Blower ran on power-up (power was restored during a heating cycle).Usually clears by itself. If it repeats, check for loose power connections or a breaker that is cutting out.
13Limit circuit lockout – the high-limit switch opened too many times.Replace a dirty air filter, open closed vents, and make sure the blower runs. Overheating usually means poor airflow.
14Ignition lockout – the furnace failed to light after several tries.Check that the gas valve on the pipe is open. A dirty flame sensor or a cracked igniter are common causes.
21Gas heating lockout – the gas valve stayed on when it should not have.Turn the furnace off and call a technician. This is a gas valve or control fault.
22Abnormal flame-proving signal – flame sensed when the gas valve is off.Call a technician. The gas valve may be leaking through.
23Pressure switch did not open – the switch is stuck closed with the inducer off.The board will not start the inducer until this clears. See our guide. Read the guide →
24Secondary voltage (24 V) fuse is open.A short in the low-voltage wiring blew the board fuse. Check thermostat wires for damage before replacing the fuse. Read the guide →
31Pressure switch did not close, or reopened – the inducer is not proving draft.Check the inducer motor, the pressure switch hose, and for a blocked vent or condensate drain. Read the guide →
33Limit circuit fault – high limit, rollout switch or blocked vent.Check the air filter and vents. If a rollout switch tripped, call a technician – it can mean a flue problem.
34Ignition proving failure – burners lit but flame was not sensed.Clean the flame sensor rod with fine steel wool and check that the furnace is properly grounded.
41Blower motor fault (variable-speed models).Check power to the blower and for anything blocking the wheel. Often needs a technician.
42Inducer motor fault (two-stage and variable-speed models).The inducer is not running at the right speed. See our inducer guide. Read the guide →
45Control circuitry lockout – the control board has an internal fault.Reset power once. If it returns, the control board usually needs replacing. Read the guide →

Goodman / Amana furnace codes

How to read them: Count the red or green LED flashes on the control board, through the door window or with the lower door off (switch off power first if you remove the door). The flashes repeat after a pause.

CodeWhat it meansWhat to check first
Steady onNormal – control has power, no fault.If there is no heat, check the thermostat setting and batteries.
OffNo power to the control board.Check the service switch, breaker, door switch and the board fuse. Read the guide →
1 flashSystem lockout – failed to ignite or lost flame too many times.Check that the gas is on, then clean the flame sensor. Turn power off for 30 seconds to reset.
2 flashesPressure switch stuck closed.The board will not start the inducer. See our guide. Read the guide →
3 flashesPressure switch stuck open – inducer running but draft not proven.Check the inducer, the pressure switch hose, the vent pipe and the condensate drain. Read the guide →
4 flashesOpen high-limit switch – furnace is overheating.Replace the air filter, open vents, and make sure the blower runs.
5 flashesFlame sensed with the gas valve off.Call a technician – the gas valve may be leaking through.
6 flashesOften: open rollout switch or blown fuse (varies by board).Check the chart on your door. A tripped rollout switch needs a technician.
7 flashesOften: low flame-sense signal (varies by board).Clean the flame sensor rod with fine steel wool.

More brands (Lennox, Rheem/Ruud, Trane/American Standard, York) are being added.